STEP VOLTAGE REGULATOR
The step type voltage regulator takes an incoming voltage that will change with load settings and maintains a constant output voltage. The voltage will drop as the loading rises along the distribution feeder. This voltage drop decreases the amount of power used by the lighting portion of the load. By increasing the voltage to this lighting load, more power is used up. They control distribution line voltages from 10% increase (boost) to 10% lower (buck) in thirty-two steps of approximately 5/8% each. The 5/8% step voltage is now a typical industry standard. There is a full range from 2400 volts (60 kV BIL) to 34,500 volts (200 kV BIL) for 60 Hz and 50 Hz system voltages and current uses. These voltage regulators can be used in more than one system voltage due to internal potential winding taps and an external ratio correction transformer on all ratings. Smaller kVA sizes are provided with support lugs for pole mounting and with substation or platform tie-down provisions. Larger sizes are delivered with substation bases with pad-mounting provisions. Static controls and the microprocessor-based control panels keep the voltage within desired limits.
- Stainless steel tank construction that provides zero corrosion.
- Sealed tank with pressure relief device for gases to escape during tap changes
- External MOV-type bypass arrester that allows higher protection to the regulator series winding from surge and system transients.
- Oil sight gauge to check oil levels and oil conditions without de-energizing the regulator
- Motor capacitor installed in the control cabinet which gives replacement without bypassing and taking the regulator out of service.
- Polarized disconnect switch (PDS) facilitates quick control installation or change out without taking the regulator out of service.
- Cover mounted terminal block gives easier access to wiring without going under oil to change tap connections.
Technical Data HM
** This is only exemplary; specifications will vary based on individual client requirements
Type | HMDK 200A | HMDK 300A | HMDK 640A | HMDK 640A HV | |
Rated current (A) | 200 | 300 | 640 | 640 | |
Max.rated through current (A) | 300 | 480 | 668 | 668 | |
Rated short-circuit withstand current (KA) |
25rsm | 6 | 7.5 | 16 | 16 |
0.85rsm | 10 | 12 | 20 | 20 | |
Peak value | 15 | 27.12 | 45.2 | 45.2 | |
Rated voltage (kv) | 24 | 27.6 | 27.6 | 35 | |
Step voltage (V) | 150 | 172.5 | 172.5 | 219 | |
Insulation to ground |
Rated lightning impulse withstand voltage 1.2/50us |
125kv | 150kn | 150kv | 200kv |
Rated power frequncy withstand voltage 50Hz, 1min |
50kv | 50kv | 50kv | 85kv | |
Number of phases | Single phases | Single phases | Single phases | Single phases | |
Frequency (Hz) | 60Hz | 60Hz | 60Hz | 60Hz | |
Max operating position | 33 | 33 | 33 | 33 | |
Mechanical life(time) | Not less than 2,000,0000 |
Not less than 2,000,000 |
Not less than 2,000,000 |
Not less than 2,000,000 |
|
Electeical life(time) | Not less than 300,000 |
Not less than 180,000 |
Not less than 180,001 |
Not less than 180,002 |
|
Operating temperature | 30°C~90°C | 30°C~90°C | 30°C~90°C | 30°C~90°C | |
Drying temperature | 120°C~125°C | 120°C~125°C | 120°C~125°C | 120°C~125°C | |
Time interval between operation | Not less than 1s | Not less than 1s | Not less than 1s | Not less than 1s | |
Weight (kg) | 22.5 | 22.5 | 33 | 36 | |
Motor parameter |
Rated Voltage (V) | 115 | 115 | 115 | 115 |
Nominal output | 20 | 20 | 20 | 20 | |
Frewuency (Hz) | 60/50 | 60/51 | 60/52 | 60/53 | |
Current (A) | 0.58 | 0.58 | 0.58 | 0.58 |
Send query
Fill out the form and we will get back to you shortly.
Automatic Voltage Regulator
An Automatic Voltage Regulator (AVR) is an electronic device that maintains a constant voltage level to electrical equipment on the same load. The AVR regulates voltage variations to deliver constant, reliable power supply.
- Fully automatic & solid control
- Wide range of choice of input voltage